Autoclave > Vertical Autoclave

Double wall Chamber for Sterilizing and Drying Fabrics, Surgical Instruments, Bottle Fluids, Ampoules & Vials
Vertical AutoclaveWorking Pressure
1.2 kg / cm2 (Gauge pressure) 121 Deg C Can also offer as High Speed Sterilizer for working Temperature 134 Deg C

Construction
Chambers & Lid - 18/8 Stainless Steel
Jacket - Heavy gauge rolled steel
Outer cover - 18/8 Stainless Steel

Unique Drying System
With the help of ejector, can create Partial vacuum upto 10 of Hg. Can also be operated on pre and post vacuum cycle / pulsing

Model and Size
Model Chamber Chamber Electric Dia. Depth. power ASC-168 400mm(16) 600mm(24) 6 kw

1. Keep the water inlet valve closed and all other open to avoid air blocks. 2. Fill water through the funnel till the red line mark on gauze glass tube. 3. Close all the valves and put the switch ON. 4. Wait till the pressure gauge (Steam Generator) builds the pressure of 22 lbs. That is 10 Kgs. 5. Load the chamber with your packs or bins. 6. Tighten the lid by slit spanner evenly. 7. Open the eject valve and allow the steam to play in the chamber. 8. Allow the chamber to build up a pressure of 17 lbs & Temp. at 121 deg C. Then close eject valve open the steam outlet valve till the pressure gauge shows 0 lb. Repeat this for two more times. Totally thrice (to pulvarise the air). 9. Adjust the canty lever to your required pressure. 10. Allow the steam to build up to your required pressure. 11. Maintain the pressure for 30 minutes at the set pressure. 12. Close the eject valve. 13. Open the steam out-let valve till the pressure gauge shows 0 lb in the chamber. 14. After showing 0 lb close the steam out-let valve. 15. Wait 10 minutes for the vacuum to build and put the current OFF. 16. Open the steam outlet valve and inlet valve to break the vacuum. 17. Open the lid with slit spanner and place the spanner crosswise between the lid and chamber for 5 to 10 minutes. 18. Open the lid and now the packs are ready for USE.

Model No. Size in mm Size in Inches
ASC-168 400 X 600 16 X 24 ELECTRIC

AUTOCLAVE- VERTICAL AUTOCLAVE (RADIAL LOCKING) DOUBLE WALLED

ASC-180, ASC-182

Vertical AutoclaveHigh pressure water steam electrically heated vertical sterilizer used for sterilization in Hospitals, Nursing Homes, Pharmaceutical Industries & Laboratories. Inner & outer chamber made of 304 Grade Stainless Steel sheet. Lid is also made of Thick stainless steel plate single piece and closed by Radial Locking & foot lifting system. All sterilizers are hydraulically tested upto 2.5 times of working pressure. Jointless neoprene/Silicon gasket does not allow any leakage. By mean of steam under pressure of 5 to 20 PSI + 3 PSI (Adjustable)complete with cord, Plug and automatic pressure control switch but without dressing bins. To work on 220 volts single Phase, 50 Hz Ac supply.

(NOTE Three phase 440V AC Supply on request).





Available in following sizes

  Dia Depth Cap. Approx. Element Load
A 250 x 450 450 mm (10x18) approx 22ltrs. 1 Nos. 2 KW
B 300 x 500 mr,.7' x 20")approx. 35ltrs. 1 Nos. 3 Kw
C 350 x 550 mm (14x22) approx 50ltrs. 1 Nos. 3 Kw
D 400 x 600 mm (16" x 24") approx 75Ltrs. 1 Nos 4 Kw
E 450 x 600 mm (18" x 24") approx 90Ltrs. 1 Nos 4 Kw
F 550 x 600 mm (22" x 30") approx 175Ltrs. 1 Nos 6 Kw
Optinal Accesories
  • Automatic low water level cut-off device
  • Digital Timer.
  • Digital Temperature Indicator.
  • Dressing Bins.
Note Other sizes on Request.

AUTOCLAVE- VERTICAL AUTOCLAVE (RADIAL LOCKING) TRIPLE WALLED

ASC-181(A), ASC-183 (A)

Vertical AutoclaveHigh pressure water steam electrically heated vertical sterilizer used for sterilization in Hospitals, Nursing Homes, Pharmaceutical Industries & Laboratories. Inner chamber, steam jacket & outer chamber made of 304 Grade Stainless Steel sheet. Lid is also made of Thick stainless steel plate single piece and closed by Radial Locking & foot lifting system. All sterilizers are hydraulically tested upto 2.5 times of working pressure. Jointless neoprene/Silicon gasket does not allow any leakage. By mean of steam under pressure of 5 to 20 PSI + 3 PSI (Adjustable) Fitted with double safety valve, water level indicator, water inlet and outlet drain valve, complete with cord, Plug and automatic pressure control switch but without dressing bins. To work on 220 volts single Phase, 50 Hz Ac supply.

(NOTE-Three Phase 440V AC Supply on request)

Available in following sizes

  Dia Depth Cap. Approx. Element Load
A 300 x 500 mm (12x20) approx 35ltrs. 1 Nos. 3 Kw
B 400 x 600 mm(16x24) approx 75Ltrs. 1 Nos 4 Kw

Optinal Accesories
  • Automatic low water level cut-off device
  • Digital Timer.
  • Digital Temperature Indicator.
  • Dressing Bins.
Note Other sizes on Request.

AUTOCLAVE- VERTICAL AUTOCLAVE (RADIAL LOCKING) TRIPLE WALLED

TRIPLE WALLED WITH STEAM STOCK

ASC-181, ASC-183

Vertical AutoclaveHigh pressure water steam electrically heated vertical sterilizer used for sterilization in Hospitals, Nursing Homes, Pharmaceutical Industries & Laboratories. Inner chamber, steam jacket & outer chamber made of 304 Grade Stainless Steel sheet. Lid is also made of Thick stainless steel plate single piece and closed by Radial Locking & foot lifting system. All sterilizers are hydraulically tested upto 2.5 times of working pressure. Jointless neoprene/Silicon gasket does not allow any leakage. By mean of steam under pressure of 5 to 20 PSI + 3 PSI (Adjustable) Fitted with Triple safety valve, water level indicator, water inlet and outlet drain valve, complete with cord, Plug and automatic pressure control switch but without dressing bins. To work on 220 volts single Phase, 50 Hz Ac supply.

(NOTE-Three Phase 440V AC Supply on request).





Available in following sizes

  Dia Depth Cap. Approx. Element Load
A 300 500 mm(12" x 22")approx 40ftrs. 1 Nos 4 Kw
B 400 600 mm (16" x 24") approx 75Ltrs. 1 Nos 6 Kw

Optinal Accesories
  • Automatic low water level cut-off device
  • Digital Timer.
  • Digital Temperature Indicator.
  • Dressing Bins.
  • High Pressure Model on request in any size mention above.
Note Other sizes on Request.